[RFC,12/24] dt: bindings: Add CSI1/CCP2 related properties to video-interfaces.txt
Commit Message
From: Sakari Ailus <sakari.ailus@iki.fi>
Document the CSI1/CCP2 properties strobe_clk_inv and strobe_clock
properties. The former tells whether the strobe/clock signal is inverted,
while the latter signifies the clock or strobe mode.
Signed-off-by: Sakari Ailus <sakari.ailus@iki.fi>
---
Documentation/devicetree/bindings/media/video-interfaces.txt | 7 ++++---
1 file changed, 4 insertions(+), 3 deletions(-)
Comments
On Mon 2016-04-25 00:08:12, Ivaylo Dimitrov wrote:
> From: Sakari Ailus <sakari.ailus@iki.fi>
>
> Document the CSI1/CCP2 properties strobe_clk_inv and strobe_clock
> properties. The former tells whether the strobe/clock signal is inverted,
> while the latter signifies the clock or strobe mode.
>
> Signed-off-by: Sakari Ailus <sakari.ailus@iki.fi>
> ---
> Documentation/devicetree/bindings/media/video-interfaces.txt | 7 ++++---
> 1 file changed, 4 insertions(+), 3 deletions(-)
>
> diff --git a/Documentation/devicetree/bindings/media/video-interfaces.txt b/Documentation/devicetree/bindings/media/video-interfaces.txt
> index f5b61bd..f0523f7 100644
> --- a/Documentation/devicetree/bindings/media/video-interfaces.txt
> +++ b/Documentation/devicetree/bindings/media/video-interfaces.txt
> @@ -114,9 +114,10 @@ Optional endpoint properties
> lane and followed by the data lanes in the same order as in data-lanes.
> Valid values are 0 (normal) and 1 (inverted). The length of the array
> should be the combined length of data-lanes and clock-lanes properties.
> - If the lane-polarities property is omitted, the value must be interpreted
> - as 0 (normal). This property is valid for serial busses only.
> -
> +- clock-inv: Clock or strobe signal inversion.
> + Possible values: 0 -- not inverted; 1 -- inverted
I'd do "clock-inverted". And probably dt people need to be cc-ed on
this one.
> +- strobe: Whether the clock signal is used as clock or strobe. Used
> + with CCP2, for instance.
Best regards,
Pavel
@@ -114,9 +114,10 @@ Optional endpoint properties
lane and followed by the data lanes in the same order as in data-lanes.
Valid values are 0 (normal) and 1 (inverted). The length of the array
should be the combined length of data-lanes and clock-lanes properties.
- If the lane-polarities property is omitted, the value must be interpreted
- as 0 (normal). This property is valid for serial busses only.
-
+- clock-inv: Clock or strobe signal inversion.
+ Possible values: 0 -- not inverted; 1 -- inverted
+- strobe: Whether the clock signal is used as clock or strobe. Used
+ with CCP2, for instance.
Example
-------