vdr-1.3.6 wrong parameter when calling shutdown script
Commit Message
Helge Lenz wrote:
> Hi,
> since I use 1.3.6 I have problems to shut my system down when there is
> no timer programmed. I tried with a plain vdr-1.3.6 and found out, that
> the "time to next timer"-parameter ($2) is not zero but it seems to be
> the negative current time as t_time. Ok, I could treat number less than
> - -72000 (recording capacity of my system) as zero, because a timer that
> startet that long ago should be finished by now, but maybe somebody
> could have a look onto this.
I just found this rather old posting in my inbox - sorry for not
getting back to you on this earlier...
I believe the fix should look like this:
Can you confirm this?
Klaus
@@ -1132,7 +1132,8 @@
cControl::Shutdown();
int Channel = timer ? timer->Channel()->Number() : 0;
const char *File = timer ? timer->File() : "";
- Delta = Next - time(NULL); // compensates for Confirm() timeout
+ if (timer)
+ Delta = Next - time(NULL); // compensates for Confirm() timeout
char *cmd;
asprintf(&cmd, "%s %ld %ld %d \"%s\" %d", Shutdown, Next, Delta, Channel, *strescape(File, "\"$"), UserShutdown);
isyslog("executing '%s'", cmd);